top of page
DIN Rail Power Supply 220V/24V/10A, ATEX ClassI Div2

DeltaPSU (Power Supply Unit)

24V 240W / DRP024V240W1AA

 

Highlights & Features

  • Universal AC input voltage
  • Power will not de-rate for the entire input voltage range
  • Power Boost of 150% for 3 seconds
  • Full corrosion resistant aluminium chassis
  • SEMI F47 certified
  • Hazardous Locations approval to ATEX and Class I, Div 2 

 

Dimensions

121 x 85 x 118.5 mm
4.76" x 3.35" x 4.67"

Unit Weight

1.04 kg (2.29 lb)

Case Chassis / Cover

Aluminium

Cooling System

Convection

 

Operating Temperature

-20°C to +80°C

Storage Temperature

-25°C to +85°C

Power De-rating

> 50°C de-rate power by 2.5% /°C,
> 70°C de-rate power by 4% /°C

Operating Humidity

5 to 95% RH (Non-Condensing)

Shock Test (Non-Operating)

IEC60068-2-27, 30G (300m/S²) for a duration of 18ms

Vibration Test (Non-Operating)

IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction

Operating Altitude

0 to 2,000 Meters (@ 50°C)

Pollution Degree

2

 

Overvoltage

32V +10%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)

Overload / Overcurrent

> 150% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)

Over Temperature

< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)

Short Circuit

Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)

Degree of Protection

IPX0

Protection Against Shock

Class I without Primary Earth connection

 

 

 

Electrical Safety

SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (under alternate part number EOE12010005 of File No. E191395), CSA to CSA C22.2 No. 60950-1 and UL 60950-1, CB scheme to IEC 60950-1

CE

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU

Galvanic Isolation

Input to Output: 4.0KVac,
Input to Ground: 1.5KVac,
Output to Gruond: 1.5KVac

Industrial Control Equipment

UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (under alternate part number EOE12010005 of File no. E315355),
CSA to CSA C22.2 No. 107.1-01
(under alternate part number EOE12010005 of File No. 181564)

Hazardous Location / ATEX

cCSAus to CSA C22.2 No. 213-M1987 and ANSI / ISA 12.12.01:2007
Class I, Division 2, Group A, B, C, D T4, Ta= -20°C to +80°C (> +50°C derating)

EN 60079-0:2009, EN 60079-15:2010 (II 3G Ex nA IIC T4 Gc, Ta= -20°C to +80°C (> +50°C derating))

 

 

INPUT:

Nominal Input Voltage

100-240Vac

Input Voltage Range

85-264Vac 120-375Vdc

Nominal Input Frequency

50-60Hz

Input Frequency Range

47-63Hz

Nominal DC Input Voltage

125-250Vdc

Input Current

< 2.90 @ 115Vac,
< 1.50A @ 230Vac

Efficiency at 100% load

> 89.0% @ 115Vac,
> 91.0% @ 230Vac

Max Inrush Current

No Damage & I²t rating at all I/P device shall not exceed their rating

Power Factor at 100% load

> 0.96@ 115Vac,
> 0.90 @ 230Vac

 

 

 

OUTPUT:

Nominal Output Voltage

24V

Output Current

10A

Output Voltage Adjustment Range

22-28Vdc

Output Power

240W

Line Regulation

< 0.5% typ. (@ 85-264Vac input, 100% input)

Load Regulation

< 1% typ. (@ 85-264Vac input 0-100% input)

Start-up Time

< 1000ms @ nominal input (100% load, 25°C)

Hold-up Time

> 20ms @ 115Vac & 230Vac (100% load, 25°C)

Dynamic Response (Overshoot & Undershoot O/P Voltage)

± 5% @ 10-100% load

Start-up with Capacitive Loads

10,000µF Max

 

DIN Rail Power Supply 220V/24V/10A, ATEX ClassI Div2

SKU: DRP024V2
  • 4 to 6 weeks on request.!

bottom of page