DeltaPSU (Power Supply Unit)
24V 240W / DRP024V240W1AA
Highlights & Features
- Universal AC input voltage
- Power will not de-rate for the entire input voltage range
- Power Boost of 150% for 3 seconds
- Full corrosion resistant aluminium chassis
- SEMI F47 certified
- Hazardous Locations approval to ATEX and Class I, Div 2
Dimensions 121 x 85 x 118.5 mm |
Unit Weight 1.04 kg (2.29 lb) |
Case Chassis / Cover Aluminium |
Cooling System Convection |
Operating Temperature -20°C to +80°C |
Storage Temperature -25°C to +85°C |
Power De-rating > 50°C de-rate power by 2.5% /°C, |
Operating Humidity 5 to 95% RH (Non-Condensing) |
Shock Test (Non-Operating) IEC60068-2-27, 30G (300m/S²) for a duration of 18ms |
Vibration Test (Non-Operating) IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction |
Operating Altitude 0 to 2,000 Meters (@ 50°C) |
Pollution Degree 2 |
Overvoltage 32V +10%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery) |
Overload / Overcurrent > 150% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery) |
Over Temperature < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) |
Short Circuit Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Degree of Protection IPX0 |
Protection Against Shock Class I without Primary Earth connection |
Electrical Safety SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (under alternate part number EOE12010005 of File No. E191395), CSA to CSA C22.2 No. 60950-1 and UL 60950-1, CB scheme to IEC 60950-1 |
CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
Galvanic Isolation Input to Output: 4.0KVac, |
Industrial Control Equipment UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (under alternate part number EOE12010005 of File no. E315355), |
Hazardous Location / ATEX cCSAus to CSA C22.2 No. 213-M1987 and ANSI / ISA 12.12.01:2007 |
INPUT:
Nominal Input Voltage 100-240Vac |
Input Voltage Range 85-264Vac 120-375Vdc |
Nominal Input Frequency 50-60Hz |
Input Frequency Range 47-63Hz |
Nominal DC Input Voltage 125-250Vdc |
Input Current < 2.90 @ 115Vac, |
Efficiency at 100% load > 89.0% @ 115Vac, |
Max Inrush Current No Damage & I²t rating at all I/P device shall not exceed their rating |
Power Factor at 100% load > 0.96@ 115Vac, |
OUTPUT:
Nominal Output Voltage 24V |
Output Current 10A |
Output Voltage Adjustment Range 22-28Vdc |
Output Power 240W |
Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% input) |
Load Regulation < 1% typ. (@ 85-264Vac input 0-100% input) |
Start-up Time < 1000ms @ nominal input (100% load, 25°C) |
Hold-up Time > 20ms @ 115Vac & 230Vac (100% load, 25°C) |
Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 10-100% load |
Start-up with Capacitive Loads 10,000µF Max |
DIN Rail Power Supply 220V/24V/10A, ATEX ClassI Div2
4 to 6 weeks on request.!